R&S®NGPL 6/5 Programmable 4-channel Power Supply
Economic Mobile Phone power supply
Specifications in Brief
| Channels | 1 to 4 |
| Constant-voltage source | |
| Voltage setting | 0 V to 6.000 V |
| Resolution | 1 mV |
| Deviation of full scale | <0.02 % ±1 mV |
| with ±10 % AC supply variation | 0.01 % |
| from 0 °C to +45 °C | 0.01 % /°C |
| with load variation of 10 % to 90 % of nominal current | 0.01 % |
| Transient recovery time with load variation of 10 % to 90 % or 90 % to 10 % of nominal current1) | <30 µs |
| Max. voltage variation during transient recovery time 1) | < ±80 mV |
| PARD2) | <3 mV (Vpp) |
| Voltage measurement | |
| DC measurement | 0 V to 6.553 V |
| Resolution | 1 mV |
| Deviation of full scale | <0.02 % ±1 mV |
| from 0 °C to +45 °C | 0.01 %/°C |
| Max. measurement rate | 16.6 measurements/s |
| Constant-current source | |
| Current setting | 0 A to 5 A |
| Resolution | 1 mA |
| Deviation of full scale | <0.02 % ±1 mA |
| from 0 °C to +45 °C | 0.01 % /°C |
| Current measurement | |
| DC measurement | 0 A to 6.553 A |
| Resolution | 100 µA |
| Deviation of full scale | <0.02 % ±300 µA |
| 0 °C to +45 °C | 0.005 %/°C |
| Max. measurement rate | 16.6 measurements/s |
| General data | |
| Voltage compensation | 1 V per load (remote sensing) |
| Nominal temperature range | 0 °C to +45 °C |
| AC supply | 90 V to 264 V AC, 47 Hz to 63 Hz, max. 500 VA |
| EMC | EN55022, Class B |
| Safety | EN61010, Class 1 |
| Output | floating, max. 120 V DC |
| Remote control interface | IEEE488.2; LAN (available soon) |
| IEEE488 interface functions | SH1, AH1, T6, TE0, L4, LE0, SR1, RL1, PP0, DCT1, DT0, C0 |
| Dimensions (W × H × D) | 483 mm × 87 mm × 445 mm (19.02 in × 3.43 in × 17.52 in) |
| Weight | 15 kg (33.07 lb) |